电话:13911250791
QQ/Wechat:fjstore
电子邮件:wliu@raid.com.cn
-
Broadcom 9560-xx 52.29.0-5442固件 2024-05-05 ======================
Supported Controllers
==================MegaRAID SAS 9540-2M2
MegaRAID SAS 9540-8i
MegaRAID SAS 9560-8i
MegaRAID SAS 9560-16i
MegaRAID SAS 9580-8i8e
MegaRAID SAS 9562-16iComponent:
==========
Release Date:
05/02/2024Version Numbers:
================
Current Package Details:
Firmware Package: 52.29.0-5442 (MR 7.29)
Firmware 5.290.00-3997
MR PL 29.250.01.00
MR CBB / NVDATA / SBR / BootCode package 5.2900.00-0761
SBR_RMC 490
BIOS package 7.29.00.0_0x071D0000_07.29.00.00
UEFI_Driver 0x071D0000 (SIGNED)
Legacy BIOS 7.29.00.0
Hii 07.29.00.00 (SIGNED)Previous Package Details:
Firmware Package: 52.28.0-5305 (MR 7.28)
Firmware 5.280.00-3972
MR PL 29.25.01.00
MR CBB / NVDATA / SBR / BootCode package 5.2800.00-0752
SBR_RMC 490
BIOS package 7.28.00.0_0x071C0000_07.28.04.00
UEFI_Driver 0x071C0000 (SIGNED)
Legacy BIOS 7.28.00.0
Hii 07.28.04.00 (SIGNED)
Bug Fixes/Enhancements:
=======================DCSG01516158 Incorrect License Options
DCSG01537426 3808N: Power customization for Generic and OEM specific profiles
DCSG01496873 PL Firmware : SAS Phy Page 0 is not showing correct values when vses disabled
DCSG01512673 Turn Off Clock for CPU 1
DCSG01507280 Fix the performance drop due to code change
DCSG01506471 7.27 PA1 - 3808N: cant set ctrl properties via storcli
DCSG01460317 BMC reset in a loop leads to controller not being detected through MCTP over I2C
DCSG01400120 Add PERST control for NVMe drives
DCSG01510133 Constant add/delete of R0 and then power off enclosure causes data abort
DCSG01550785 Invalid Enclosure ID was observed when NVMe drive was hotplugged to 9580 card
DCSG01488049 PL Fault During IO and Driver Load/Unload
DCSG01488430 Add Firmware Version 28 for PartNumber 15987 to PSoC Catalog Image
DCSG01546839 Read(32) or Write(32) CDB sent to NVMe drive reported incorrect additional sense code
DCSG01520805 Backend PCIe: ED91 fault on hot reset
DCSG01517111 UseIdleSas12G was not set in Hardware even when it was set in the ExtManPage40
DCSG01516427 Fails controller firmware download if detect wrong type
DCSG01510048 Fix the configurable Physical Disk count issue
DCSG01455484 Fix compilation for different targets
DCSG01459879 Improve Copyback disable handling while copyback is in progress on drives
DCSG01072582 SCSI Self-Test Results (0x10) log page not updating status when self-test in progress
DCSG01521501 94xx/95xx PL Spinup: Incorrect write to register to clear the spinup interrupt
DCSG01350001 PL firmware not failing NVMe self-test when already an existing NVMe self-test command is in progress
DCSG01488468 3808N: Cross Reference Architecture Spec Enabled Features with Latest PoC Code
DCSG01476347 Firmware Exception during IO with JBOD Cable Pulls
DCSG01451450 [95xx]: Incorrect slot number management for non-UBM backplanes
DCSG01488467 3916N: Re-enable Full DDF
DCSG01440304 Fix the unwanted blocking of reverting of a hot spare drive after copy back
DCSG01523695 OEM Controller is not booting and stuck during Enclosure Initialization with switch
DCSG01538008 Build all failed on firmware int code
DCSG01525592 VMware OS reported IOMMU Fault iMR controller while running virtual machine IOs VM and controller reset
DCSG01463291 Enhance discovery state machine to complete slot mapping before a drive is inserted.
DCSG01442264 Spinup failed drives (Bad drives) are not seen in LSA/CLI Tool
DCSG01516217 Continuous MCTP command failure with a bad drive in topology leads to controller not being detected through MCTP over I2C on OEM config
DCSG01419594 SLT-Emulator2.0-OOB option all is not showing valid information
DCSG01516607 Maximum spans per virtual drive incorrect
DCSG01454893 MegaRAID 7.25 Beta-Assertion failure in ddf module
DCSG01508452 Observed hang in SAS only and NVMe only mode in 3808N controller after adapter reset.
DCSG01489940 Kill adapter during firmware upgrade and Downgrade with IO.
DCSG01358471 Expander based backplane is not updating page 0xA on drive pull/insertion
DCSG01547639 Firmware: SAS/SATA only firmware for 95xx HBA family
DCSG01467130 [9500] SAS_IO_UNIT_CONTROL/SEND_PRIMITIVE command fails for the phys with PCIe support enabled
DCSG01445968 Update Secure boot Library in Firmware
DCSG01512905 Add new chip entry for 3808N controller.
DCSG01467624 Controller dies after running Snapdump in a loop with 23 nvme drive R5 and IO stress
DCSG01470476 Overnight reading the snapdump OnDemand in a loop, caused iMR Controller not found error
DCSG01454021 Support Drive firmware download without using Host Memory
DCSG01515787 Block the access to disabled Hardware cores on 3808N adapter while dumping pl dbg.
DCSG01516045 zip file created in response to zc megamon command is corrupted
DCSG01151757 SL OOB: NVME response buffer is not displaying user requested size of response buffer.
DCSG01458287 Fix Channel compilation due to OEM changes
DCSG01521548 Updated Firmware to support SCSI to NVMe Translation Spec 1.10
DCSG01487334 Fix snapdump being interrupted due to the time of searching through events
DCSG01533800 NVMe: handle vendor specific failure condition
DCSG01449669 Set jbod shows successful, but jbod does not appear to be created
DCSG01467248 PL Firmware: Bring up of OEM specific EDSFF UBM Backplane.
DCSG01480400 VSES Commands hung during the drive pull test with IOs.
DCSG01462382 Add New Firmware Versions for OEM PartNumbers 15984, 29652, and 25934 to PSoC Catalog Image
DCSG01450318 Controller diag firmware changes from Apps DF: DCSG01444219
DCSG01505532 3808N make firmware changes for new architecture specification updates
DCSG01486559 Virtual SES IOs aren't failed if a UBM I2C transfer error occurs during LED update
DCSG01477125 NVDATA major version was updated to be same as Phase Version
DCSG01551132 NVDATA switch to enable the PDB0B core for 3808 N controller
DCSG01427369 Cable management diagnostic command shows incorrect data for some cables
DCSG01516125 Fix controller setting for support for capacity expansion without adding disks
DCSG01522625 Manual Crash Dump fails when iMR N card is in the test-configuration.
DCSG01443947 [95xx] Reduction in default maximum resource count values in Runtime Configuration Parameters for Enclosures and Expanders
DCSG01588354 Update NVDATA Major Version for Ph30
DCSG01524005 Enhance firmware logging to include PL logs from initial discovery at start of day to address Drive lost across reboots
DCSG01309777 Added duplicate MID protection support to multi-LUN drives
DCSG01446403 LCS work around in PL firmware to be made generic for all models of an OEM specific UBM backplane.
DCSG01481344 NVRAM space to persist information related to certain Redfish Alerts
DCSG01531437 [95xx] NVMe Drive firmware update failed if the drive firmware payload size is more than 2Mb and 32k aligned
DCSG01511337 fix excessive unlocking of secured drive when clearing drive restricting
DCSG01418256 Add support for OEM Backplanes
DCSG01511102 Cache Bypass Modes shown on iMR when there is no write back possible
DCSG01419839 A target reset Task Management to a direct attach SAS drive may not go out to the drive even though PL thinks it has
DCSG01471791 7.26: Firmware found Enclosure exceeds max supported, caused KA on M.2 Ctrl
DCSG01373026 POC: New profile and licensing control & display for the new boot controller
DCSG01524008 Update SCSI to NVMe translation to version 1.10
DCSG01458189 [95xx]: Log sense page 0x15 fails on ACS-5 supported SATA drive.
DCSG01542341 Pulling low power mode NVMe drive causes PL Fault
DCSG01481110 MegaRAID 7.26 Alpha: Data abort during unexpected power loss test with copy back
DCSG01523599 Simultaneous Read/Write Miscompare: Data Read Does Not Match Data Written
DCSG01464478 Add timer module debug functionality in Snapdump module
DCSG01469541 Fix I2C OOB processing null pointer due to I2C reset
DCSG01470940 Snapdump: Add reason codes when clearing
DCSG01480248 Support controller firmware download without using host memory
DCSG01505033 7.27: Drive Pull R1 Hits Exception Handler Called Error
DCSG01506370 When slot is set to non installed firmware does not report enclosure slot bad status
DCSG01435858 Fix the hanging of NVMe passthrough command when request is too big for the controller to handle
DCSG01468284 7.26 PA2: crashdump.txt is taking longer than 15s to generate for ondemand snapdump
DCSG01509009 3808N should block hotspare option in LSA
DCSG01508464 Added Serdes Config Parameters to ExtManPage40
DCSG01454043 Firmware: Production of iMR on 3808N without host memory dependency.
DCSG01453955 Power customization support for SAS3808N board.
DCSG01467889 Non 512 Mutiple ReportZone request cause 0 data transfer but completes successfully.
DCSG01547099 NVMe: a certain NVMe 2.0 device fails to initialize
DCSG01437689 Assertion failure noted in timer module during SATA pass through and IOs test over 2 days
DCSG01471837 Enable Security and controller IO MFC settings for the new boot contoller
DCSG01489595 Fix Ses device not ready handling path
DCSG01377905 Firmware:9540N POC: memory and DDF management changes
DCSG01516095 9500 Series: Fault 0x5805 Invalid Message Frame Index Seen after multiple resets
DCSG01539401 Drives Show up as UGUnsp
DCSG01494307 Firmware: Ensure that IT firmware can not run on the 3808N
DCSG01365348 Series 95xx POC: Remove host memory with SnapDump
DCSG01421204 [95xx] Added feature to override the firmware control of PERST# signal to NVMe drives using NVDATA.
DCSG01531972 Task management failure and assertion seen during hard reset test on JBODs
DCSG01504986 Assertion failure noted in timer module : further root cause of DF: DCSG01437689
DCSG01490785 7.26: 3916N partition failed when create raid 0/1 using NVME drive
DCSG01521495 Updated 'Summary Release Notes' document
DCSG01469813 7.26 PA2: some Snapdump prints flood the uart
DCSG01507596 Firmware crashes when reading the UBM controller information when the UBM controller is in non operational mode.
DCSG01571422 Support external key management over OOB on 9560 with SafeStore and SED drives
DCSG01533403 7.x - OEM specific custom build target environment addition
DCSG01494319 PL support for Direct GPIO LED management.
DCSG01559620 Fix set PCIe lane speed without checking phy validity
DCSG01472315 Long running task for back ground operation are completed to the MC.
DCSG01572396 Snapdump CRC replay debug
DCSG01571116 PL: Firmware failed assertion check for some NVMe drive models
DCSG01520376 Implemented debug function to skip UEFI driver handshake wait
DCSG01589449 Add Firmware Version 23 for PartNumber 29652 to PSoC Catalog Image
DCSG01470015 JBOD volumes link is enabled for Drive resource in RDE
DCSG01602093 Add Firmware Version 25 for PartNumber 29652 to PSoC Catalog Image
DCSG01471998 Added support to send VolumeOffline and VolumeOfflineCleared RDE events when drives get locked and reprovisioned respectively
DCSG01557573 RMC changes for SAS3816
DCSG01542197 Battery Charging Redfish Event is not generating for redfish battery status for Broadcom controllers
DCSG01462821 Blocking of Drive Write Cache for NVMe drives is removed for a particular OEM
DCSG01460306 Removed IML Codes
DCSG01460218 Display empty array for dedicated spare drives and operations for JBOD volumes when RDE GET is issued.
DCSG01571779 Fix 'Static Analysis Tool' reported items in Firmware
DCSG01525592 VMware OS reported IOMMU Fault iMR controller while running virtual machine IOs VM and controller reset
DCSG01503334 Assertion failure seen in Firmware timer module
DCSG01556598 7.27 Beta: drive not seen in storcli after quick pull push with IO and rebuild going on
DCSG01461751 Implement support to update Controller Rates using RDE
DCSG01598659 Add Firmware Version 24 for PartNumber 29652 to PSoC Catalog Image
DCSG01489940 Kill adapter during firmware upgrade and Downgrade with IO.
DCSG01488473 PLDM Firmware Download: Assertion failure in ..\cpu\arm\exceptions.c at line 1046 on triggering QueryDeviceidentifier command in Download state
DCSG01507674 PLDM Type 5 - NVMe drive firmware version is not updated after successful update
DCSG01573644 Wrong Check Added by ER DCSG01558994 for Disabling SAS on 3808N
DCSG01614816 Handle Link isolation on PL initiated task management timeout
DCSG01539651 7.27 3808N: Data abort exception during media error injection test with 4k drives, system can't boot since OS behind controller as well
DCSG01485699 Reduce MegaRaid HDD sequential read performance
DCSG01472892 Send ControllerOK Redfish Event when ControllerDegraded event was logged earlier
DCSG01576996 9540-16i controller is not generated snapdump on OEM server when start of day PL logs capture feature is set
DCSG01462783 PLDM firmware update on drive fails when there are different drive models are connected to the controller
DCSG01588333 OOB Firmware Flash Fails
DCSG01561805 Battery relearn starts/completes in a loop after clearing nvram
DCSG01496206 BatteryOK RDE alert was logged after every AC power cycle of the server
DCSG01473533 Add support for VolumeOffline and VolumeOfflineCleared Redfish Enhanced Alerts
DCSG01521525 Replaced OEM specific max supported physical devices with profile max supported devices in some of the loops
DCSG01615981 RMC Fix for DCSG01598480
DCSG01490067 Implement target ID and sysPD cooldown timer and bypass option for iMR
DCSG01461749 Added support for OEM specific generic backplane
DCSG01466479 Redfish - Implement new Controller Alerts
DCSG01458117 Add support for 'Availability' state set for controller composite sensor
DCSG01460483 RDE - Add new RDE alerts adhering to Storage Device Message Registry 1.1.0
DCSG01556638 Direct attached Lane break test failed on Gen4 NVMe U.2 drive
DCSG01588354 Update NVDATA Major Version for Ph30
DCSG01542190 DriveOfflineCleared Redfish Alert not posted after SED imported with a different Key
DCSG01582911 9540-16i controller firmware sending a lot prints rolling while capturing snapdump
DCSG01601124 NVRAM: Add fields to track phy state to support Link Isolation feature
DCSG01440232 Enhance NVMe Shutdown Timeouts
DCSG01502940 REST client does not display details of copyback operation on drive
DCSG01496212 Predictive failure RDE alert for a drive was logged twice on a single server reboot or controller reset
DCSG01562181 Host boot failure caused a UEFI hang on some systems
DCSG01486632 Firmware: Disk pending defects count support added
DCSG01492588 PLDM firmware update on UBM5 backplane is failing with timeout error
DCSG01464314 During AC Power Cycle Test, I2C Error Occurs
DCSG01576748 Use Direct GPIO LED management if the 3808N Device LED Management policy is set.
DCSG01547753 First time data capture trigger time properties print change
DCSG01523599 Simultaneous Read/Write Miscompare: Data Read Does Not Match Data Written
DCSG01465244 Defect fixes and the associated fixes found during Static Code Analysis
DCSG01458622 Add OEM customizations for Generic Features
DCSG01546055 3808N: 7.27: firmware hitting kill adapter during logical drive check consistency
DCSG01540194 Drive Gets Marked Bad During Reset Test
DCSG01547626 Link Isolation feature support to avoid one fault drive affecting RAID card functionality
DCSG01540844 Foreign drives are not accessible in the RDE client
DCSG01558994 Disable SAS on OEM Boards
DCSG01567599 CRC failure on modules captured under snapdump
DCSG01531576 Redfish - Exception seen with secure foreign drives during reboot
DCSG01603980 VD creation on a particular drive fails with firmware fault
DCSG01548367 Set batterywarning succeeds on narrow controller which does not support battery
DCSG01544525 Request for additional information about host PCIe from OOB
DCSG01569025 MegaRAID 7.28: firmware assertion in timer module while running MCTP out of band communication
DCSG01531972 Task management failure and assertion seen during hard reset test on JBODs
DCSG01480038 RDE - Incorrect HTTP error code displayed for Redfish CREATE operation without JSON body
DCSG01571660 Enable PCD eFuse Runtime Check for 3808N
DCSG01528863 Drives are marked as Unconfigured Bad in 9540 controller during the hot-plug test.
DCSG01570991 Help commands being shown instead of useful information in start of day snapdump
DCSG01571899 Build all failed on firmware int code
DCSG01574223 Commands Failed on NVMe Drives
DCSG01552620 Fix unwanted warning message of debug flag
DCSG01507594 Secured spanned Virtual disk creation is successful.
DCSG01580987 Fix drive firmware download timeout due to slow OOB download
DCSG01535249 [IN776543]Improper product name for UBM5 BP
DCSG01558739 MegaRaid 7.27 Program - New release/build target addition for OEM specific program
DCSG01587543 MCTP discovery : Set EID request timeout
DCSG01561751 PLDM Flashing Exception
DCSG00013257 HW Workaround:HW_SETTINGS_CHANGE : PCIe PHY LF setting should be changed from 16 to 15
DCSG00108561 Clean up SBR Build Tools
DCSG00068041 SBR Build date and time corrected
DCSG01335479 Update Source to Latest and Fix Uninitialized Variable
DCSG01618357 Updated OEM NVDATA
DCSG01568048 OEM Needs Multi-VSES Enabled in NVDATA via SubOEMID
DCSG01574298 Enable Feature for OEM
DCSG01559023 Created new OEM HWBIC.
DCSG01227412 M.2 controller does not report slot numbers for two drives properly.
DCSG01223238 Setting suboemID to 0xC causes the controller to fault
DCSG01574292 Updated OEM HWBICs
DCSG01574297 Remove PCIe setting from OEM HWBIC.
DCSG01526064 9580-8i8e NVMe drives not detected on internal ports
DCSG01083355 MegaRAID 9561-16i
DCSG01493657 Incorrect Slot Numbers on M.2 Controllers
DCSG00026388 Fix storcli Output Compare for Ventura vs Aero
DCSG00026403 Fix HWBIC BSP CBB Names to Reflect EVT vs DVT
DCSG01490624 Update OEM HWBIC
DCSG01547628 Individual control of drive fault LEDs for direct attached drives in boot solution
DCSG01043351 Aero MR: allow user to ON/OFF ALARM using StorCLI
DCSG00041568 not applicable
DCSG01571423 Enable Feature for OEM
DCSG01177800 ReleaseOrderPkg:DCSG01176818 failed to include the rebranded new type of 9561-xx
DCSG01621422 Modified OEM HWBIC Setting
-
Broadcom 95xx最新固件下载 2023-01-02 StorCLI version 7.2307.0000.0000 or later can be used to upgrade the PSoC component.Controller FW package 52.20.0-4341 or later must be first installed on the adapter.Due to hardware changes on the below adapters, after upgrading to after upgrading iMR/HBA to any MR 7.22 (52.22.x-xxxx) orlater package, downgrading to MR 7.21 or older (52.21.x-xxxx, 52.20.x-xxxx, etc.) is not allowed.*****************************************************************************************************************************************************PLEASE READ THESE GUIDELINES FOR HBA CONTROLLERS (9500-xx)*********************************************************************************************************************************************************************StorCLI version 7.2307.0000.0000 or later can be used to upgrade the PSoC component.Controller FW package P24 24.00.00.00 or later must be first installed on the adapter.******************************************************************************************************************************************************************************************************************************************************======================Supported Controllers:======================MegaRAID 9560-8iMegaRAID 9560-16iMegaRAID 9580-8i8eMegaRAID 9562-16iMegaRAID 9540-8iMegaRAID 9540-16iHBA 9500-8iHBA 9500-16iHBA 9500-8eHBA 9500-16eHBA 9502-16iComponent:=========PSoC Catalog Firmware v1.25 (DCSG01375926)Release date: 12/05/2022Version Numbers:===============PBLP_HBA_P4_Version_HW:1.00_FW:10.00_PN:14790PBLP_HBA_P4S423_Version_HW:1.00_FW:10.00_PN:14798PBLP_HBA_P4S443_Version_HW:1.00_FW:10.00_PN:06021PBLP_RAID_P5_Version_HW:3.00_FW:27.00_PN:15987PBLP_RAID_P5Init_Version_HW:3.00_FW:27.00_PN:12345PBLP_RAID_P5OCP_Version_HW:8.00_FW:3.00_PN:25731PBLP_RAID_P6_Version_HW:10.00_FW:18.00_PN:29211PBLP_RAID_P6Travis_Version_HW:11.00_FW:18.00_PN:29651